  • Standardized A-Scan ultrasound certified by Prof. K. Ossoinig
  • Unique software for internal reflectivity analysis and characterization of tissues
  • Available with B mode, UBM and biometry modes

OVERVIEW

 

Image quality first

High resolution digital imaging, with the latest probe technology.

Its high signal to noise ratio helps differentiate the finest structures at all frequencies.

Wide range of probes

Flagship ultrasound system from Quantel Medical, Aviso S offers a large choice of probe frequencies to cover a wide range of applications:

  • 10MHz -> Visualization of the entire globe
  • 20MHz -> High resolution imaging of the perpendicular wall and posterior pole
  • 25MHz -> Linear scanning probe for anterior segment visualization
  • 50MHz -> Linear UBM probe for glaucoma diagnosis

Easy to use

Examination is fast and easy using Aviso S software via touchscreen remote or the computer terminal.

Exclusive Standardized Echography

Technique for tissue characterization

Standardized echography with Aviso S provides detailed and crucial information the eye, orbit and ocular annexes including:

  • Internal reflectivity of the structures
  • Location and dimension of the structures
  • Tissue differentiation
  • Certified by Prof K. Ossoinig

B-Scan examination at 10 and 20 MHz

Management of patients with trauma, uveitis, vitreoretinal disorders and differentiation of intraocular tumors

A-Scan biometry

  • Routine use prior to cataract surgery
  • Axial length measurement (easy with
  • Auto+Save Mode) and IOL calculation with all formulas

UBM examination at 25 and 50 MHz

  • Management of anterior chamber disorders
  • Analysis and Diagnosis of glaucoma

Standardized A Scan

  • Unique tissue differentiation
  • Unparalleled tumors and mass lesions diagnosis in eye and orbit

Image Quality First

Quantel Medical's unique electromagnetic probe technology combined with the high signal to noise ratio guarantees the best image resolutions at all frequencies.

The unique acoustic zoom feature helps enhancing visualization of the vitreous andfinest details at 10 and 20 MHz.


Image Quality First

Examination is fast and easy using the Aviso S software via touchscreen remote or the computer terminal:

  • Simple, intuitive workflow through easy software navigation with full screen imaging and miniature reference images available during examination
  • Quick and easy labelling of probe positioning and pathology localization with two eye diagrams
  • Unlimited number of scans per session, saved and exported in image or video (Cineloop) format
  • Automatic video recording of the last 40 seconds of examination to review and select the best image frame
  • High performance post-processing image tools, including complete semi-automated tools for glaucoma diagnosis: AOD 500 & 750, TIA, IT 750 & 2000, ARA 500 & 750, TISA 500 & 750, LV

Standardized A Probe

A specific parallel beam probe with the same sound intensity along length of scan with an 8 MHz narrow band receiver

Unique Technology for Standardized

S Curve

An S curve amplifier that combines adequate acoustic acuity and perfect acoustic field allowing for precise visualization of reflectivity levels

Unique Tissue Model

A unique tissue model is used to calibrate the probe, which standardizes tissues Sensitivity measurements for consistent and accurate diagnosis


Unique and Extensive Diagnosis Capabilities

 

Detect intraocular and orbital lesions quickly and reliably

Tumor Q1: measure mass lesions, automatic calculation of tissue internal reflectivity, calculation and visualization of angle Kappa.

Calculate muscle thickness

Muscle Profile: calculate the thickness of the six muscles to obtain muscle indexes.

Differentiate retinal or other membrane detachment

Retina A1: automatic diagnosis support that recognizes specific levels of reflectivity for retina and other membranes.

Retina Q2: for quantitative differential calculation.

SPECIFICATIONS

B Scan Modes

B Mode

Grey levels:  256
Adjustable gain:  20 to 110 dB
Time Gain Control (TGC):   0 to 30 dB
Manual and synchronized dynamic range adjustment 25 to 90 dB
Unlimited storage capacity for still images and video seq.:  up to 40 second duration
Image post-processing tools: Algorithmic & color image filters, calipers, areas, angles, markers, comments
Glaucoma quantifying semi-automated tools: 

AOD 500 & 750, IT 750 & 2000, TIA, ARA 500 & 750, TISA 500 & 750, LV


Posterior Pole

Magnetic 10 MHz probe

Transducer frequency:  10 MHz
Angle of exploration:  50°
Depth of exploration:  20 to 60 mm 
Focus:  21 to 25 mm 
Axial resolution:  150 μm
Lateral resolution:  300 μm
Frame rate acquisition:  up to 16 Hz

Magnetic 20 MHz probe for posterior pole*

Transducer frequency:  20 MHz
Angle of exploration:  50°
Focus:  24 to 26 mm 
Axial resolution:  100 μm
Lateral resolution:  250 μm
Frame rate acquisition:  up to 16 Hz

UBM

Magnetic 50 MHz UBM probe with linear scaning

Transducer frequency:   50 MHz
Linear transducer movement:  exploration width 16 mm (0.63”)
Focus:  9 to 11 mm (0.35” to 0.43”)
Axial resolution:  35 μm
Lateral resolution:   60 μm

Linear 25 MHz UBM probe

Transducer frequency:   50 MHz
Linear transducer movement:  exploration width 16 mm (0.63”)
Focus:  11 to 13 mm (0.35” to 0.43”)
Axial resolution:  70 μm
Lateral resolution:   120 μm

Biometry

Adjustable gain:  20 to 110 dB
Time Gain Control (TGC):   0 to 30 dB

11 MHz probe

Transducer frequency:  11 MHz
Tip diameter:  6 mm (0.23”)
Electronic resolution:  0.03 mm (0.001”)
Depth: 40/80 mm sur 2048 points
Contact and immersion techniques compatible  
Aiming beam:  LED or laser pointer*

Axial length measurements

Ultrasound propagation velocity adjustable per segment (anterior chamber, lens, vitreous) and IOL and vitreous material

Built-in pattern recognition:  dense, phakic, aphakic, PMMA, acrylic and silicone material for pseudo-phakic eye types
Automatic calculation of standard deviation and average total length series of 10 measurements
Acquisition modes:  automatic, auto + save, manual 
Automatic detection of scleral spike  

IOL Calculation

SRK-T, SRK 2, HOLLADAY, BINKHORST-II, HOFFER-Q, HAIGIS
Post-op refractive calculation:
- Pre-op and Post-op refraction, Pre-op and Post-op keratometry
- 6 different methods for keratometric correction and implant calculation:
History derived, refraction derived, contact lens method, Rosa regression, Shammas regression, Double K/SRK-T (Dr. Aramberri’s formula)
7 values bracketed for desired ametropia for each IOL (IOL increment steps: 0.25D or 0.50D)
Simultaneous display of 4 different IOL calculations


Standardized A Mode

Unique mode of standardized echography

Digitally programmed S-shaped amplifier characteristics and comprehensive design  criteria for standardized echography and tissue differentiation according to Karl C. Ossoinig MD.

Automatic tissue sensitivity determination with specific gain value recorded.

Diagnosis functions featuring: Tumor Q1 ; Retina A1/Retina Q2; Musc Profile
Probe Frequency: 8 MHz / parallel beam
Cineloop in A mode: Sequence up to 400 images recorded
Depth: Orbit 80 µs, Eye: 40µs, Zoom 20 µs

Distance measurement between 2 gates with adjustable velocity

Axial length measurement with cornea, A.C. depth, lens and vitreous differentiation.


GENERAL

General Information

Connexion
Connectable to PC systems via USB-2 port operating under Windows 8 / Windows 7
Dedicated software for communication driving between the acquisition module and computer
Images displayed on the computer monitor
 
Electrical requirements
Power supply: 100-120 / 200-240 Vac
± 10% single phase + grounding
Frequency: 50 / 60 Hz
Power: 25 VA max
 
Features
Overall dimensions: 19 cm (L) x 17 cm (W) x 19 cm (H)
7.5” (L) x 6.7” (W) x 7.5” (H)
Touch screen dimensions: 8.6 cm (W) x 11.5 cm (H)
3.4” (W) x 4.5” (H)
Weight: 1.5 kg (3.3 lb.)
 
* Option

Data Management

Built-in physician and patient database
Exportation of still images and video sequences
Customizable digital and printed reports
DICOM* and/or EMR compatible
Compatible with PC, USB video and DICOM printers

Inquiry about this product
A/B Mode, UBM and Standardized A Mode Aviso S

You Recent View Items
VI Congreso Internacional de Optometría Ecuador

VI Congreso Internacional de Optometría Ecuador

Bascom Palmer 2018

Bascom Palmer 2018

American Academy of Ophthalmology 2018

American Academy of Ophthalmology 2018

5555 NW 74 AVE.
MIAMI. FL. 33166
P: 305-882-0120
F: 305-882-0140
sales@mercoframes.net
Skype mercoframesonline
Skype sales3mercoframes
Skype helpmercoframes
Whatsapp +1 305-882-0120
Hangouts ale@mercoframes.net
Terms and Conditions