A/B/S/UBM Ultrasound Platform ABSolu - Quantel medical

A/B/S/UBM Ultrasound Platform ABSolu

New Product
Share
Hits 68
  • 20Mhz B probe with 5 ring annular array technology
  • Enhanced UBM imaging
  • Patented motion sensor in B probes and UBM
  • DICOM standard display

NEW ANNULAR IMAGING

Quantel Medical has made a decisive leap forward with a new 5 ring annular technology on a 20 MHz probe. The principle is to emit alternating ultrasounds by 5 concentric transducers located in a single probe.

The images thus obtained are spectacular as the entire eye is now visible with an exceptional level of detail.


A SINGLE MULTIFUNCTION PROBE

The annular 5 ring 20 MHz B probe:


  • Increases depth of field by 70%,
  • Increases lateral resolution by 27%,
  • Maintains high axial resolution.

The annular technology allows to simultaneously examine pathologies of the vitreous, the retina and the orbital part.


NEW UBM IMAGING

UBM technology makes it possible to diagnose the structures behind the iris, that other technologies cannot visualize.

Quantel Medical now offers optimised UBM technology:

  • New signal processing for enhanced resolution and penetration,
  • Linear transducer motion to optimise image quality,
  • Electromagnetic technology to increase speed acquisition and comfort of use,
  • Clearscan™ compatible: rapid and comfortable examination.

INTEGRATED MOTION SENSOR

The B15, B20 and UBM probes are equipped with a position sensor that provides real-time essential information such as:


  • The position of the probe on the eye,
  • The direction of the ultrasound beam.

This helps the operator to identify the area of examination more rapidly.


REDESIGNED USER INTERFACE

REDESIGNED USER INTERFACE

DICOM IMAGING

A world premiere in ophthalmic ultrasound:

new Full HD screen withgreyscale display compliant with section 1A of the DICOM standard.


  • Constant and standardised image quality
  • Reliable image interpretation

ABSWitch


8 FUNCTION WIRELESS FOOTSWITCH


  • Adjustable Gain (+ and -).
  • Freeze/unfreeze image.
  • Viewing of Cineloop images (forward and reverse function).
  • Images saved in the patient's file.
  • Tag on the Cineloop.

SPECIFICATIONS

B SCAN MODES

B Mode

Grey levels:  256
Adjustable gain:  20 to 110 dB
Adjustable Time Gain Control (TGC):   0 to 30 dB
Adjustable dynamic range: adjustement from 25 to 90 dB (for 15 and 50 MHz - 80 dB for 20 MHz 5A)
Image post-processing tools: filters (algorithm and colors), calipers, areas, angles, markers, comments
Glaucoma quantifying semi-automated tools: 

AOD 500 & 750, TIA, IT 750 & 2000, ARA 500 & 750, TISA 500 & 750, LV

Cineloop in B mode:

up to 400 images


Posterior pole examination

Magnetic 15 MHz probe

Transducer frequency:  15 MHz
Angle of exploration:  50°
Depth of exploration:  60 mm (2.36'')
Focus:  24 mm (0.94'')
Depth of field:  12 mm (0.47'')
Axial resolution:  115 µm  
Lateral resolution:  400 µm 
Frame rate acquisition:  up to 16 MHz

Magnetic Annular 5 rings 20 MHz probe

Transducer frequency:  20 MHz - Annular 5 rings
Angle of exploration:  50°
Depth of exploration:  60 mm (2.36'')
Focus:  22 mm (0.87'')
Depth of field:  20 mm (0.47'')
Axial resolution:  80 µm  
Lateral resolution:  200 µm 
Frame rate acquisition:  up to 16 Hz

UBM & Anterior segment examination

Magnetic 50 MHz UBM probe with linear scanning

Transducer frequency:   50 MHz
Linear transducer movement:  16 mm (0.63”)
Focus:  10 mm (0.39”)
Axial resolution:  35 μm
Lateral resolution:  60 μm

Standardized A Mode

Digitally programmed S-shaped amplifier characteristics and comprehensive design criteria for standardized echography and tissue differentiation according to Karl C. Ossoinig, MD. Automatic tissue sensitivity determination with specific gain value recorded.

Diagnosis functions featuring: LESION Q1, Retina A1, Retina Q2, muscular profile with Optic nerve measurements
Probe frequency: 8 MHz parallel beam
Cineloop in A mode: up to 400 images
Depth: orbit 80 µs, eye: 40µs, Zoom 20 µs

Distance measurement between 2 gates with adjustable velocity.


BIOMETRY

Adjustable gain:  20 to 110 dB
Time Gain Control (TGC):   0 to 30 dB

11 MHz probe

Transducer frequency:  11 MHz
Tip diameter:  6 mm (0.23”)
Electronic resolution:  0.04 mm (0.001”)
Depth of exploration: 40/80 mm sur 2048 points
Contact and immersion techniques compatible  
Aiming beam:  LED or laser pointer*

Axial length measurements

Ultrasound propagation velocity adjustable per segment (anterior chamber, lens, vitreous) and IOL and vitreous material

Built-in pattern recognition:  phakic, Dense/Long, aphakic, PMMA, acrylic and silicone material for pseudo-phakic eye types
Automatic calculation of standard deviation and average total length series of 10 measurements
Acquisition modes:  automatic, auto + save, manual 
Automatic detection of scleral spike  

IOL Calculation

SRK-T, SRK 2, HOLLADAY, BINKHORST-II, HOFFER-Q, HAIGIS

Post-op refractive calculation:

  • Pre-op and Post-op refraction, Pre-op and Post-op keratometry
  • 6 different methods for keratometric correction and implant calculation:

History derived, refraction derived, contact lens method, Rosa regression, Shammas regression, Double K/SRK-T (Dr. Aramberri’s formula)

9 values bracketed for desired ametropia for each IOL (IOL increment steps: 0.25D or 0.50D)

Simultaneous display of 4 different IOL calculations

Inquiry about this product
A/B/S/UBM Ultrasound Platform ABSolu

You Recent View Items
VI Congreso Internacional de Optometría Ecuador

VI Congreso Internacional de Optometría Ecuador

Bascom Palmer 2018

Bascom Palmer 2018

American Academy of Ophthalmology 2018

American Academy of Ophthalmology 2018

5555 NW 74 AVE.
MIAMI. FL. 33166
P: 305-882-0120
F: 305-882-0140
sales@mercoframes.net
Skype mercoframesonline
Skype sales3mercoframes
Skype helpmercoframes
Whatsapp +1 305-882-0120
Hangouts ale@mercoframes.net
Terms and Conditions