Unmatched world-wide: The CARDIOVIT AT-10 plus combines resting ECG, exercise ECG, pacemaker measurement, HRV analysis, signal averaged ECG analysis, thrombolysis software and spirometry in a single system – like its legendary predecessor, the CARDIOVIT AT-10.
The AT-10 plus is made by SCHILLER, a world-leading manufacturer of cardiopulmonary diagnostic systems. Combining high quality and easy operation, the unit can be used wherever ECG and spirometry data must meet highest demands.
There is a reason why its famous predecessor, the CARDIOVIT AT-10, is used in many clinics and practices and even in the international space station ISS and its control centres. NATO armies also place their trust in SCHILLER‘s quality. They use more than 20,000 units world-wide.
All this at the touch of a button – and even networkable!
The CARDIOVIT AT-10 plus is ready to use at any time! Direct function keys and on-screen menus allow for quick, simple and reliable operation. Preprogrammed settings are activated at the touch of a button. You can define your preferred settings for monitor and paper outputs once and store them at the press of a key. This speeds up both the learning and operation.
SCHILLER offers you several standard programs. You can thus complement the CARDIOVIT AT-10 plus by proven software options according to your individual needs.
The SCHILLER ECG measurement program generates precise average complexes, determines the beginning and end points of P waves, QRS complexes and T waves, and provides accurate time and amplitude measurements.
With the SCHILLER ECG interpretation program, one of the best-documented existing algorithms, you have at your disposal a broad range of diagnostic information with regard to rhythm, electrical axis, QRS morphology changes, QRS blocks, hypertrophy characteristics, ST or T changes, myocardial infarction characteristics etc.
With an analysis time of less than 5 seconds, the SCHILLER ECG interpretation software ranks among the fastest and most accurate programs on the market!
The CARDIOVIT AT-10 plus records the signals of all 12 ECG channels over the past 5 minutes. This reduces the risk that important rhythm data might be overlooked.
To save paper, you can transmit the full-disclosure view of a 5-minute recording to the SCHILLER SEMA-200 data-management system on your PC for editing or printout.
This advanced program measures the pacing frequency, performs individual measurement of pulse width for atrial and ventricular stimulation, and determines the AV intervals.
With this SCHILLER program, you can determine the risks (e.g. of sudden cardiac death) for a cardiopathic patient – after a recording time of only 1 to 60 minutes. In addition to the graphic display of RR tachograms and histograms, numerous statistical parameters are calculated (e.g. standard deviation, mean deviation, mean value, BB50 value). All parameters are shown in relation to the mean RR interval – absolutely unique!
The signal averaged ECG analysis makes it possible to detect micropotentials after a QRS complex. Such signal averaged ECGs may be an indicator of ventricular tachycardia or even sudden cardiac death – in particular for patients who have suffered cardiac infarction. This program option offers a handy alternative to more common invasive techniques.
This option creates a numerical assessment of the ECG measurement, to help determine the probability of acute cardiac ischaemia. It gives you important additional diagnostic information for patients with chest pain.
The most commonly used test protocols are already programmed in your CARDIOVIT AT-10 plus. Five (treadmill) or four (bicycle) user definable protocols allow you to store or modify programs exactly as you wish. The exercise testing program controls a bicycle ergometer or treadmill. Noninvasive blood pressure measurement is taken automatically at the beginning of every load stage or at freely definable intervals, and indicated on the monitor and on printouts. The blood pressure can be measured using the BP-200 plus or the BP recorder integrated with the ERG 911 (optional).
Continuously updated ECG information, including the heart rate, stage number and duration, exercise period, load and METs are displayed on-screen and documented on the printout. A comprehensive final report is printed out at the end of each exercise test. The advanced evaluation program EXEC provides you with continuous 12-lead ST information during the test and a comprehensive final report.
Measured values Slow spirometry: SVCin, SVCex, SVCmax, ERV, IC, IRV ... Forced Spirometry: FVC, FEV1, FEV6, FEV1/FVC, FEV1/FEV6, FEF25-75%, PEF, MEF75%, MEF50%, MEF25%, FEF25%, FEF50%, FEF75%, FEF0.2-1.2, FMFT, FIVC, PIF ... MVV: MVV, RR, TV |
Presentation - Flow/volume loop - Flow/loop curve - Volume/time curve - Measurements table - Interpretation programs |
Predicted values (standard values) - Adults: ECCS, Forche97, Berglund, Finnland, Indien, Hankinson (NHANES III), Knudson/ITS, Knudson76/ITS, Crapo 1981, Morris/ITS, Composite, Polgar - Paediatric: Quanjer & Tammeling, Forche97, Indien, Knudson/ ITS, Knudson76/ITS, Polgar, Hankinson (NHANES III) - Comparison pre/post medication possible - Extrapolated predicted values Standards: ATS, ERS |
SPIROVIT SP-250/SP-260 pneumotach flow sensor for spirometry tests: |
Dimensions: 118 x 36 x 28 mm, approx. 120 g |
Measuring method: Pneumotach sensor |
Measuring range: - Flow: 0 to +/- 14 l/s - Volume: 0 to +/- 11 l |
Measurement accuracy: in accordance with ATS/ERS |
Flow impedance: < 0.2 mbar * s/l at 12 l/s |
ECG and spirometry in one unit – this is unique world-wide! The CARDIOVIT AT-10 plus can be transformed into a proven table spirometer for the measurement, recording and assessment of the flow-volume and volume-time curves and the corresponding parameters. Several expiratory and inspiratory tests can be performed and compared with country specific normal values. Pre/post measurements and interpretation are standard. Two flow sensors are available for the portable all-rounder. You decide whether you prefer working with the proven pneumotachograph SP-250 or SP-260.
The SP-250 flow sensor sets a new hygiene standard, reducing the risk of cross contamination to its minimum. It is small, lightweight, inexpensive and easy to operate. You are ready for the next test within seconds. Insert the new sensor – done. Safe and convenient for you and your patients.
The Sensor can easily be disassembled to clean the parts. It is reassembled and ready for the next patient in no time.
Via SEMA-200, the CARDIOVIT AT-10 plus can easily be integrated with existing hospital information systems (HIS) to enable an optimum workflow. In only four steps, you can record and archive a new ECG.
The built-in WLAN module enables the wireless network interconnection of the CARDIOVIT AT-10 plus. For mobile application in the clinic.
SCHILLER - THE ART OF CONNECTIVITY
Since 1987, SCHILLER has connected its ECG units to the IT world in numerous clinics and practices, and is known as a pioneer in this area. The CARDIOVIT AT-10 plus features all required modules to communicate with its environment, be it via Ethernet, modem or WLAN.
Comprehensive network interconnection gives you access to the SCHILLER SEMA-200 cardiology information system, optimising the workflow and enhancing the unit‘s functionality. By using the network, you can work more efficiently and receive additional support for your clinical decisions.
With the worklist option, you can directly access a patient‘s ECG recordings at any time, which gives you more flexibility in your examination and treatment.The optional WLAN function enables the bi-directional communication with SEMA-200. You can quickly and easily view, edit and archive patient data, reducing the risk of data entry errors.
The AT-10 plus offers you safe wireless connections via standard WLAN protocols such as 802.11 g, WPA, WPA II or WEP. WLAN communi-cation is also available with invisible SSID. SCHILLER devices support DHCP or static IP to protect your patient’s privacy. Even if all safety measures should fail during data transmission, the patient data cannot be read because it is encrypted by SCHILLER.
System |
Dimensions: 348 x 288 x 87 mm (l/w/h) |
Weight: Approx. 4.2 kg including rechargable battery and paper |
Electrical data: |
Power Supply: Mains or battery operation |
Voltage: 100 to 240 V |
Power: 0.3 A (115 V) to 0.16 A (240 V) |
Sampling: 50/60 Hz |
Battery type: Lithium-ion rechargable battery, replaceable by the user; battery capacity for 100 ECG printouts or 4.5 hours of continuous display (without printing) |
Battery recharging time: Approx. 6 hours after full sicharge (with monitor switched off) |
Power consumption: 14 to 28 VA |
Line frequency filter: Distortion-free suppression of superimposed 50 or 60 Hz sinusoidal interferences by adaptive digital filtering |
ECG amplifier: - Sampling frequency: 4000 samples/second/channel - Measuring range: Dynamic +/- 10mV, DC +/- 300 mV - Pacemaker detection: > +/- 2 mV / duration > 0.1ms - Frequency range: 0Hz - 150Hz (IEC/AHA) - CMRR: > 100dB - Digital resolution: 5μV / 12bit - Input impedance: 100MOhm - Patient leakage current: < 5μA - Patient input circuit: Fully floating and isolated, defibrillation protected - Defibrillation protection: 5000VDC |
Special functions: - Detection of loose electrodes, electrode impedance, overvoltage, AC noise, baseline fluctuations and muscle tremor - Heart rate measurement: 30-300 bpm; heart rates exceeeding this range are not displayed |
Standard Interface: |
Interface for exercise ECG control: |
- 1 x RS-232 for bicycle ergometer - 1 x RS-232 for treadmill - 1x RS-232 for NIBP (BP-200plus) |
DC: |
- DC input 0.5 V/cm - DC output 0.5 V/cm |
RS-232 (V24) serial interface: Spirometry (Spirovit sensor 250 or 260) |
VGA video connection: External LCD connection |
QRS-Trigger Output: TTL, +/- 10V |
Communication: |
SCM (SCHILLER Communication Module): Communication with SEMA-200 via the internal RJ-45 Interface - USB - Optional internal modem/fax - Optional internal WLAN module |
Internal memory: 350 ECG data |
Long-term rhythm recording: |
5 minutes memory: In the memory, the signals of the past 5 minutes can be saved over all ECG channels and transmitted to SEMA |
Filters: - Myogram filter: Adjustable to 25 or 35 Hz - SSF: SCHILLER Smoothing Filter - SBS: SCHILLER Baseline Stabiliser |
Display: |
Display type: Backlit colour LCD, diagonal 10.4 in (264 mm) |
Display resolution: 800 x 600 pixels |
Display data: Heart rate, patient name, patient number, time, curves, lead designations, speed, amplification, filter settings and warnings |
Number of displayed leads: 3, 6 oder 12 |
Lead combinations: Up to 16 simultaneous leady: Standard/Cabrera/Nehb; more lead combinations freely programmable by the user |
Printer: |
Printing technology: High-resolution thermal printing, 8 dots7mm (amplitude axis), 40 dots/mm (time axis), @ 25 mm/s |
Frenquency range: 0Hz - 150Hz (IEC/AHA) |
Chart speed: 5, 12.5, 25 & 50 mm/s |
Sensitivity: 5, 10, 20 & 40 mm/mV |
Paper type: Thermo-reactive, Z-folded, 14 x 21 cm (DIN A4 ; letter size) |
Writing breadth: 3 to 7 recording channels positioned at optimal width on 200 mm, automatic baseline adjustment |
Keyboard: |
Type: User-friendly, splash- and dustproof foil keyboard with softkeys and alphanumeric keys |
Hardware options: |
- Ergometer (ERG-911) - Treadmill (MTM-1500) - Blood pressure recorder (BP-200plus or ERG-911) - Instrument trolley (UNICART 1 or 2) - Suction Electrode system (VAC-100) - Transport case - Barcode scanner - Internal WLAN on SCM - Integrated modem/fax on SCM |
Software options: |
- ECG interpretation: Software C™ ECG analysis software for adults and children - Pacemaker measurement - High-resolution signal-averaged ECG (SAECG) - Heart rate variability (HRV) - Thrombolysis software - Exercise ECG (EXEC II™) - Spirometry - Worklist - Vector cardiography (combined with SEMA-200) |
Standards: |
Environmental conditions: |
Temperature: Operation: 10° to 40° C ; transport/storage: -10° to 50° C |
Relative humidity: Operation: 20 % to 95 % noncondensing; transport/ storage: 15 % to 95 % noncondensing |
Pressure: Operating: 700 to 1060 hPa; transport/storage: 500 bis 1060 hPa |
Certification: |
Protecting class: I according to IEC 60601-1, with internal battery, IIa according to Directive 93/42EWG |
Safety Standard: CF according to IEC 60601-1; IEC 60601-1, IEC 60601-1-2, IEC 60601-2-25, IEC 60601-2-51, EN 60068-2-27, ANSI/ AAMI EC11 |
Conformity: CE according to Directive 93/42EWG |
Warranty: |
Standard warranty period is one year |
Accessories: |
All our accessories are available at www.mercoframes.com |