Laser Flare Meter KOWA FM-700 - Kowa

Laser Flare Meter KOWA FM-700

Friendly for both users and patients.

KOWA Laser Flare Meters are designed to be the best partners.

The Kowa FM-700 is an aqueous flare meter with a slit-lamp design. Even in cases of corneal inflammation, anyone with slit lamp experience will find the alignment process intuitively easy. It is also applicable for monitoring patients post cataract surgery and for testing ocular inflammatory diseases such as uveitis.

Features

  • Quantitative measurement of protein concentration in aqueous humor with high accuracy using the laser scattering technique
  • Clinical tests for uveitis and other ocular inflammations, and to monitor post cataract surgery
  • Non-contact and non-invasive testing

Principle

An area including the measurement window is scanned with a laser beam. Background signal 1 (BG1) is obtained when the laser beam is located below the measurement window and background signal 2 (BG2) is obtained when the laserbeam is located above the measurement window. Both are scattered light noise from intraocular tissue, whilst the flare signal (SIG) is a sum of scattered light from protein and scattered light noise from intraocular tissue.

Thus, the intensity of the scattered light caused by the protein concentration in the aqueous humor of the anterior chamber is calculated using the formula: SIG-(BG1+BG2)/2. The result obtained from using this formula is called ‘flare value Eand represented as photon count per millisecond.

Specifications: FM-700
Binokulares stereoskopisches Mikroskop Binocular stereoscopic microscope Vergrößerung 7,10,16,26,40x Magnification 7,10,16,26,40x
Dioptrien Ausgleichs-Bereich des Okulares Dioptres Compensation range of the eyepiece ±5D ±5D
Augenabstandseinstellung eye-to-eye distance adjustment 55 – 72mm 55 – 72mm
Spaltbreite slit width 0 – 11mm kontinuierlich 0 - 11mm continuous
Spaltlänge slit length 1 – 9mm kontinuierlich 1 - 9mm continuous
Blendendurchmesser aperture diameter Ø0,5mm, Ø11mm Ø0.5mm, Ø11mm
Messbereich measuring range 1 – 500 Photonenanzahl/ms 1 – 500 photon counts/ms
Messgenauigkeit measurement accuracy ±5% (bei 80 Photonenanzahl/ms) ±5% (bei 80 photon counts/ms)
Beobachtungslichtquelle observation light source Halogenlampe (12V, 30W) Halogen lamp (12V, 30W)
Für Flaremeter for Flaremeter Laserdiode (640nm, 35μ W) Laser diode (640nm, 35μ W)
Licht Detektor Photomultiplier (PMT) Light Detector Photomultiplier (PMT)
Drucker Printer Thermischer Liniendrucker mit automatischer Papier-schneide-Funktion Thermal line printer with automatic paper cutting function
Druckerpapier printer paper 58mm breit 58mm width
Monitor Monitor 4,3"inch" TFT Farb LCD Monitor 4.3inch TFT Color LCD Monitor
Schnittstelle Interface RS-232C RS-232C
Abmessungen/Gewicht Dimensions/Weight 600 (B) x 460(L) x 560 (H)mm / 25kg 600 (W) x 460(L) x 560 (H)mm / 25kg
Stromanschluss power supply AC100 - 230V, 50 / 60Hz AC100 - 230V, 50 / 60Hz
Stromverbrauch power consumption 60VA / 80VA (maximum) 60VA / 80VA (maximum)
VIDEOS
  • Kowa FM-700 video

Inquiry about

Accept Terms and Conditions
Laser Flare Meter KOWA FM-700
Laser Flare Meter KOWA FM-700

You Recently Viewed Items

Events / Shows View All

AAO 2023
AAO 2023

AAO 2023

Bascom Palmer 2023
Bascom Palmer 2023

Bascom Palmer 2023

Reunión virtual con el Dr. Julian Triviño (Colombia)
Reunión virtual con el Dr. Julian Triviño (Colombia)

Reunión virtual con el Dr. Julian Triviño (Colombia)

AAO 2021
AAO 2021

 Friday, Nov. 12 - Monday, Nov. 15  Ernest N. Morial Convention CenterNew Orleans, LA.

5555 NW 74 AVE.
MIAMI. FL. 33166
P: 305-882-0120
F: 305-882-0140
sales@mercoframes.net
Skype mercoframesonline
Skype sales3mercoframes
Skype helpmercoframes
WhatsApp +1 305-882-0120
Hangouts ale@mercoframes.net